VDB2HWDB-JBLXX-1-XOK1 [Carling Technologies]

Rocker Switch, DPDT, On-on, Maintained, 15A, 24VDC, Quick Connect Terminal, Rocker Actuator, Panel Mount,;
VDB2HWDB-JBLXX-1-XOK1
型号: VDB2HWDB-JBLXX-1-XOK1
厂家: Carling Technologies    Carling Technologies
描述:

Rocker Switch, DPDT, On-on, Maintained, 15A, 24VDC, Quick Connect Terminal, Rocker Actuator, Panel Mount,

开关 光电二极管
文件: 总14页 (文件大小:2011K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
V-Series  
V-Series  
CONTURA II, III SWITCHES  
The V-Series Contura II & III snap-in rocker switches offer countless unique options including choices for  
ratings, circuits, colors, illuminations and symbols. These single or double pole switches feature removable  
actuators in a choice of actuator styles and colors, and can be illuminated with either square or bar shaped lenses.  
Actuators may be purchased and stocked separately. An optional plug-in terminal connector enables pre-wiring  
of wire harnesses.  
The Contura switches with sealed option, are certified to IP66/68, signifying complete protection against dust  
and prolonged spray and submersion under pressure, and are recognized to UL1500 - Ignition Protection  
for Marine Products. These switches are vibration, shock, thermoshock, moisture and salt spray resistant.  
Temperature ratings range from -40°C to +85°C.  
Resources:  
Download 3D CAD Files  
IGS  
STP  
Watch Product Video  
Product Highlights:  
Countless options for ratings, circuits, colors,  
illuminations and legends  
Typical Applications:  
Š
Š
Š
Š
Š
On/Off Highway Equipment  
Marine  
Š
Military Armored Vehicles  
Mining Machinery and Equipment  
Any application requiring environmental  
protection  
Š
Certified to IP66/68 for front panel components  
Š
Vibration, shock, thermoshock, moisture and salt  
spray resistant  
Š
Temperature range from -40°C to +85°C.  
Carling Technologies, Inc.  
60 Johnson Avenue, Plainville, CT 06062  
Email: sales@carlingtech.com  
Application Support: team2@carlingtech.com  
Phone: 860.793.9281 Fax: 860.793.9231  
www.carlingtech.com  
|
2
V-Series Contura Sealed Rocker Switches - Design Features  
V-Series Switch  
DESIGN FEATURES  
INTERCHANGEABLE ACTUATORS  
Panel redesign is a snap with our wide  
range of rocker styles. Achieve maximum  
design variety with minimum inventory.  
Simply swap rockers to create an entirely  
new look for your panel.  
DUAL SEAL PROTECTION  
CLEAN CONNECTIONS  
Seals out water, dust,  
Options for both eight and ten  
terminal base styles with AMP &  
Packard compatible connectors  
affords myriad circuit options  
while providing ease of assembly.  
debris, and enables switch  
certification to IP66/68 for  
front panel components.  
MULTIPLE LIGHTING OPTIONS  
BRASS ROLLER PIN  
Robust mechanism  
eliminates the need for  
lubricants. Enables switch  
to withstand -40°C to  
+85°C temperatures.  
SILVER PLATED BUTT  
CONTACT MECHANISM  
Providing 50k to 100k  
electrical cycles and  
a variety of different  
electrical ratings.  
OPTIONAL PANEL SEAL  
Prevents water/dust  
ingress behind panel.  
In addition to Incandescent  
lamps, our LED illumination is  
offered in a wide array of light  
intensities, colors, as well as  
dual level, tri-color, and flashing  
options.  
*Manufacturer reserves the right to change product specification without prior notice.  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
V-Series Contura Sealed Rocker Switches - Actuator Options & Accessories |  
3
Contura II & III  
Contura X  
The Contura II & III actuators are  
constructed of thermoplastic  
The raised bracket/bezel on the  
Contura X helps prevent inadvertent  
actuation of the rocker, as well as  
preventing debris from being trapped  
under the actuator. This curved rocker  
style is available with a variety of  
lenses and legends.  
polycarbonate and are offered with  
a hard nylon overlay or a “soft-touch”  
elastomer overlay. These models  
incorporate aesthetic designs on  
the top and bottom of the rocker  
featuring two rows of raised “bumps”  
on the Contura II and three “indented”  
lines on the Contura III.  
Contura IV  
Contura XI  
The Contura IV’s “Shape to create  
a Shapeactuator works with the  
curves, contours & advanced styling  
of the latest panel designs, flowing  
with these advanced curves & radii.  
This actuator style fits on the Contura  
flush bracket/bezel.  
The raised bracket/bezel on the  
Contura XI helps prevent inadvertent  
actuation of the rocker, as well as  
preventing debris from being trapped  
under the actuator. This convex style  
rocker is available with a wide variety  
of lenses and legends.  
Contura XII  
Contura V  
The Contura XII version features a  
paddle style actuator with the raised  
bracket/bezel of Contura X and XI. The  
contoured handle design provides  
intuitive recognition and ease of  
operation and is available with all  
Contura X and XI lens and legend  
offerings.  
The symmetrically curved Contura  
V actuator provides the perfect  
complement to the Contura IV’s  
“Shape to create a Shapedesign  
concept. With its flush style mounting  
bracket, Contura V can be mounted in  
between two Contura IV’s, by itself, or  
in groups.  
Contura VI (WAVE)  
Contura XIV  
The Contura VI WAVE sealed rocker  
switches, when used in a row, create  
an uniquely appealingwavedesign  
on your panel. A variety of colors and  
finishes are available for both rocker  
and wave insert. Contura VI features  
bar and oval lenses.  
The Contura XIV represents a sleek new  
crossover rocker design which should  
appeal to Trucks, Buses and Heavy  
Vehicles as well as the Marine Industry.  
Intuitive feel is provided by recessed  
ridges along with a Center Groove  
which effectively defines the boundary  
between top and bottom switch  
functions.  
Contura VII  
Illuminated Indicators  
Contura VII featuring gently  
& Accessories  
curved corners and edges assuring  
compatibility with most any panel  
design. Intuitive feel is maximized  
by the use of 2 embossed circular  
pads located at opposite ends of  
the rocker. Any combination of Bar  
or Oval style lenses can be located  
in the pads providing a truly unique  
look, exclusive to Contura VII.  
Alert operator of systems functions  
or malfunctions, are offered with  
removable/replaceable lamps in  
Contura II, II, V or X styles. Accessories  
include connectors, mounting panels,  
hole plugs, panel seals, and actuator  
removal tools. Refer to accessories page  
for full details  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
|
4
V–Series Contura Sealed Rocker Switches - General Specifications  
Electrical  
Contact Rating  
Agency Certifications  
.4VA @ 24VDC (MAX) resistive  
15 amps, 125VAC  
10 amps, 250VAC  
1/2 HP 125-250VAC  
20 amps, 4-14VDC  
15 amps, 15-28VDC  
10A, 14VT  
Environmental  
Sealing  
Sealed version: IP66/68, this rating  
applies to front panel components of  
the actual switch only, and signifies  
complete protection against dust as  
well as powerful jets of water.  
Mixed Flowing Gas (MFG) Class III  
3 year accelerated exposure per  
ASTM B-827, B-845 Silver and gold  
contacts  
6A, 125VAC L  
1500 Volts RMS  
50 Megohms  
Dielectric Strength  
Insulation Resistance  
Initial Contact Resistance 10 milliohms max. @ 4VDC  
Corrosion  
Life  
50,000 - 100,000 cycles circuit  
dependent  
Silver alloy, silver tin-oxide, fine  
silver  
Brass or copper/silver plate 1/4”  
(6.3mm) Quick Connect  
terminations standard. Solder lug,  
Wire Lead  
Contacts  
Terminals  
Operating Temp.  
Vibration 1  
-40°C to +85°C  
Per Mil-Std 202F, Method 204D  
Test Condition A 0.06 DA or 10G’s  
10-500 Hz. Tested with VCH connector.  
Test criteria - No loss of circuit during  
test, pre and post test contact  
resistance.  
Mechanical  
Vibration 2  
Resonance search  
24-50 Hz 0.40 DA  
Endurance  
150,000 cycles minimum  
circuit dependent  
50-2000 Hz ±10 G’s peak  
Horizontal Axis 3-5 G’s max.  
Random  
Physical  
24 Hz 0.06 PSD-Gsq/Hz  
Lighted  
Incandescent - rated 10,000  
hours Neon - rated 25,000 hours  
LED - rated 100,000 hours 1/2 life  
(LED is internally ballasted for  
voltages to 24VDC)  
60 Hz 0.50  
100 Hz 0.50  
200 Hz 0.025  
2000 Hz 0.025  
No loss of circuit during test; <10μ  
seconds chatter.  
Seals  
Base  
Internal  
Optional external gasket panel seal  
Polyester blend rated to 125°C with  
a UL flammability rating of 94V0.  
Hard Surface: Basic actuator  
structure molded of thermoplastic  
polycarbonate with a hard Nylon 66  
thermoplastic surface overlay.  
Soft Surface: Basic actuator structure  
molded of thermoplastic polycarbonate  
with an elastomer overlay.  
Shock  
Per Mil-Std 202F, Method 213B, Test  
Condition K @ 30G’s. Tested with  
VCH connector. Test criteria - No loss  
of circuit during test, pre and post  
test contact resistance.  
Contura II,III,IV,V,  
VI, VII Actuator  
Salt Spray  
Dust  
Per Mil-Std 202F, Method 101D, Test  
Condition A, 96 Hrs. Sealed version only.  
Mil STD 810, Method 510.2 Air Velocity  
300 Ft/Min Duration 16Hr  
Per Mil-Std 202F, Method 107F, Test  
Cond. A, -55°C to +85°C. Test criteria -  
pre and post test contact resistance  
Per Mil-Std 202F, Method 106F, Test  
Criteria - pre and post test contact  
resistance  
All Contura switches with sealed  
construction meet the requirements  
of UL1500/ISO8846 for ignition  
protection, in addition to  
conformance with EC directive  
94/25/EC for marine products.  
Thermal Shock  
Contura X,XI,XII Actuator,VP Nylon 66 Reinforced rated to 105°C  
Lens  
Contura XIV  
Polycarbonate rated at 100°C  
Polycarbonate lens/sub-rocker with  
ABS shell  
Moisture Resistance  
Ignition Protection  
Actuator Travel (Angular Displacement)  
2 position  
3 positions  
18°  
9° from center  
Mounting Specifications  
Panel Thickness Range  
.830[21.08]  
Gaskets Acceptable Panel Thickness  
0
1
.030 to .250 (.76 to 6.35mm)  
.030 to .109 & .147 to .157  
(.76 to 2.77mm & 3.73 to 3.98mm)  
TEST CUT  
HOLE IN  
ACTUAL  
1.450[36.83]  
MATERIAL  
Recommended: No gasket with panel  
thickness of .032, .062, .093, .125,.187 or .250  
SWITCH  
MOUNTING HOLE  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
V-Series Contura Sealed Rocker Switches- Contura II & III - Ordering Scheme |  
5
V 1 D A B T 0 B A R B 00 0 00  
8
9
10  
Lens  
11  
Color  
12  
Legend  
13  
Legend  
Orientation Lens Legend  
14  
Actuator  
1
2
3
4
5
6
7
Bracket  
Actuator  
Series  
Circuit  
Rating  
Termination Illumination Lamp  
Lamp  
6,7 LAMP (SAME CODING FOR BOTH SELECTIONS)  
1 SERIES  
Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6  
V
No lamp  
Neon  
0
1 125VAC 2 250VAC  
Incandescent 4 3V  
5 6V  
6 12V  
7 18V  
8 24V  
2 CIRCUIT  
Terminal Connections as viewed  
from bottom of switch: SP - single pole - uses terminals 1, 2 & 3.  
8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6.  
8 - - 7  
1 - - 4  
2 - - 5  
3 - - 6  
LED*  
Red  
superbright superbright  
( ) - momentary  
Amber  
Green  
Red  
R
2VDC  
A
B
C
D
L
F
G
H
J
6VDC  
M
N
P
S
8 - - 7  
1 - - 4  
2 - - 5  
3 - - 6  
10 - - 9  
Terminals 7, 8, 9 & 10 for lamp circuit only.  
12VDC  
24VDC  
T
V
* Consult factory for “daylight bright” LED options. Typical current draw for  
LED is 20ma.  
Position:  
1
2
Connected Terminals  
NONE  
3
1 & 2, 4 & 5  
OFF  
1
8 FLUSH BRACKET COLOR , PANEL SEAL  
SP DP  
2 & 3, 5 & 6  
ON  
Black  
B
C
White  
W
Y
Gray  
G
H
1
2
3
4
5
6
7
8
A
B
C
D
F
No Seal  
One Seal  
(ON)  
ON  
NONE  
OFF  
NONE  
(OFF)  
ON  
ON  
NONE  
ON  
NONE  
(ON)  
J
ON  
OFF  
ON  
9 ACTUATOR  
K
L
ON  
OFF  
(ON)  
0
No Actuator  
Contura II  
Contura III  
(ON)  
OFF  
(ON)  
A, B  
C, D  
SPECIAL CIRCUITS  
H*  
2 & 3  
2 & 3, 5 & 4  
2 & 3  
5 & 4  
OFF  
3,6  
1,4  
G*  
S*  
M*  
R*  
E*  
2 & 3, 5 & 6  
2 & 3, 5 & 6  
(2 & 3, 5 & 6)  
(2 & 3, 5 & 6)  
5 & 6  
Actuator orientation above terminals:  
2 & 3  
1 & 2  
OFF  
2 & 3  
2 & 3  
2 & 1  
5 & 1  
10 LENS  
5 & 3  
0 - No Actuator  
Z - No Lens  
*Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in  
selection 4. External jumper between terminals 2 & 4 for circuit E are  
provided by customer. Circuit E may be used for SP OFF-ON-ON circuit.  
Clear White Amber Green Red Blue  
1
2
3
4
5
6
7
8
9
A
8
G
H
J
K
L
M
N
P
R
S
T
C
D
E
F
U
V
W
Y
3
3 RATING  
1
.4VA @ 28VDC Resistive  
15A 24V  
B
C
D
E
F
Lens color for LEDs must be clear, white, or match color of LED.  
Green or blue lenses are not recommended with Neon lamps.  
20A 18V  
20A 12V  
20A 14V, 10A 14VT (circuit 1, 4 , A & D only)  
10A 14V, 6A 14VT (circuit G only)  
.4VA/20A 12V  
1
M
N
11 ACTUATOR COLOR AND TEXTURE  
.4VA/15A 24V  
0 - No Actuator  
Black  
B
C
Gray  
G
H
Red  
R
S
White  
W
Y
Soft Surface  
Hard Surface  
4 TERMINATION / BASE STYLE  
8 term 10 Term  
Termination  
Jumper  
1
2
.250 TAB (QC) no barriers  
.250 TAB (QC) with barriers  
.250 TAB (QC) no barriers  
Solder Lug no barriers  
Solder Lug  
Wire Leads no barriers  
Wire Leads  
No  
2
A
J
B
K
5
No  
Yes T2 to 5  
No  
No  
No  
No  
12 ACTUATOR LENS OR BODY LEGENDS  
11 ON 12 OFF 13 I  
OFF ON  
14 O  
3
O
I
C
5
D
6
F
15 O O 16 O O 17 O I 18 I O  
F N  
F
N
F
F
E
Note: Codes J & K for circuits H, G & M.  
For additional legend options & codes, visit us at www.carlingtech.com.  
5 ILLUMINATION  
13 LEGEND ORIENTATION  
Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals  
3 & 6 end of switch. Positive (+) and negative (-) symbols apply to LED  
lamps only  
0
1
2
3
4
No legend (used with codes 11-18 in selection 12)  
Orientation 1  
Orientation 2  
Orientation 3  
Orientation 4  
Sealed Unsealed Lamps  
Illumination Type Lamp wired to Terminals  
S
A
B
C
D
0
1
2
3
4
NONE  
1
1
2
1
2
1
2
1
2
1
2
2
1
2
INDEPENDENT 8 (+) 7 (–)  
DOWN  
UP  
3 (+) 7 (–)  
3 (+) 7 (–)  
3 (+) 7 (–)  
1 (+) 7 (–)  
1 (+) 7 (–)  
3 (+) 7 (–)  
DOWN  
DOWN  
UP  
1
2
3
4
E
F
5
6
7
UP  
INDEPENDENT 8 (+) 7 (–)  
14 ACTUATOR LENS LEGEND  
00  
UP  
3 (+) 6 (–)  
No legend this location / no actuator  
G
INDEPENDENT 8 (+) 7 (–)  
(used with codes 11-18 in selection 12) Selection 14 required when switch  
requires two legends. If the two legends consist of one lens and one  
body legend, lens legend must be specified in selection 12; body legend  
specified in selection 14.  
UP  
3 (+) 7 (–)  
H
U
Z
Y
INDEPENDENT 8 (+) 7 (–)  
INDEPENDENT 8 (+) 7 (–)  
INDEPENDENT 10 (+) 9 (–)  
For legend options & codes, visit us at www.carlingtech.com.  
SINGLE POLE SWITCHES ONLY  
Notes:  
J
8
1
2
1
2
DOWN  
3 (+) 8 (–)  
Consult factory to verify horsepower rating for your particular circuit choice.  
INDEPENDENT 6 (+) 7 (–)  
INDEPENDENT 8 (+) 7 (–)  
INDEPENDENT 6 (+) 7 (–)  
1
2
Custom colors are available. Consult factory.  
K
W
Body legends not available on Soft surface actuators; White imprinting is standard  
on black actuators; Black imprinting is standard on white, red and gray actuators.  
Custom colors are available, consult factory.  
DOUBLE POLE SWITCHES ONLY  
L
9
R
T
1
1
1
2
1
2
DOWN  
UP  
3 (+) 6 (–)  
3 (+) 6 (–)  
3 (+) 6 (–)  
1 (+) 4 (–)  
1 (+) 4 (–)  
3 (+) 6 (–)  
3
4
Additional ratings available. See V-Series Switch Accessories page.  
Contura II available with two square lenses. Consult factory for details.  
M
N
DOWN  
DOWN  
UP  
P
V
UP  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
|
6
V-Series Contura Sealed Rocker Switches - Contura II & III Locking - Ordering Scheme  
V 1 D A S W 0 B A Z E 00 0  
8
9
10  
Lens  
11  
Function  
12  
Legend  
13  
1
2
3
4
5
6
7
Bracket  
Actuator  
Legend  
Orientation  
Series  
Circuit  
Rating  
Termination Illumination Lock  
Lamp  
1 SERIES  
V
7 LAMP  
Lamp above terminals 3 & 6 end of switch  
No lamp  
Neon  
0
1 125VAC 2 250VAC  
Incandescent 4 3V  
5 6V  
6 12V  
7 18V  
8 24V  
2 CIRCUIT  
LED*  
Red  
superbright superbright  
Terminal Connections as viewed  
( ) - momentary  
Amber  
Green  
Red  
R
from bottom of switch:  
SP - single pole - uses terminals 1, 2 & 3.  
2VDC  
A
B
C
D
L
F
G
H
J
8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6.  
6VDC  
M
N
P
S
8 - - 7  
1 - - 4  
2 - - 5  
3 - - 6  
8 - - 7  
1 - - 4  
2 - - 5  
3 - - 6  
10 - - 9  
Terminals 7, 8, 9 & 10 for lamp circuit only.  
12VDC  
24VDC  
T
V
* Consult factory for “daylight bright” LED options. Typical current draw for  
LED is 20ma.  
Position:  
1
2
3
1
8 FLUSH BRACKET COLOR , PANEL SEAL  
SP DP  
2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5  
Black  
B
C
White  
W
Y
Gray  
G
H
1
4
6
7
8
9
A
D
J
ON  
ON  
NONE  
NONE  
OFF  
OFF  
ON  
No Seal  
One Seal  
ON  
ON  
K
L
ON  
(ON)  
OFF  
OFF  
(ON)  
(ON)  
ON  
OFF  
1
N
NONE  
9 HARD SURFACE ACTUATOR  
SPECIAL CIRCUITS  
Black Gray Red  
White  
H
H*  
2 & 3  
2 & 3, 5 & 4  
2 & 3  
5 & 4  
OFF  
Contura II  
Contura III  
A
B
G
G*  
S*  
M*  
R*  
E*  
2 & 3, 5 & 6  
2 & 3, 5 & 6  
(2 & 3, 5 & 6)  
(2 & 3, 5 & 6)  
5 & 6  
2 & 3  
1 & 2  
OFF  
C
D
E
F
2 & 3  
3,6  
1,4  
2 & 3  
2 & 1  
5 & 1  
Actuator orientation above terminals:  
5 & 3  
*Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in  
selection 4. External jumper between terminals 2 & 4 for circuit E are  
provided by customer. Circuit E may be used for SP OFF-ON-ON circuit.  
10 LENS  
Z - No Lens  
Clear White Amber Green Red Blue  
3
8
D
J
P
V
4
3 RATING  
1
.4VA @ 28VDC Resistive  
15A 24V  
20A 18V  
20A 12V  
Lens color for LEDs must be clear, white, or match color of LED.  
Green or blue lenses are not recommended with Neon lamps.  
B
C
D
E
F
M
N
1
11 ACTUATOR LOCK FUNCTION AND COLOR  
20A 14V, 10A 14VT (circuit 1, 4 , A & D only)  
10A 14V, 6A 14VT (circuit G only)  
.4VA/20A 12V  
3
Lock Color  
Match Actuator  
Black  
Up  
A
Down  
Up & Down  
Center  
H
J
R
S
1
2
3
4
5
B
.4VA/15A 24V  
White  
C
K
L
T
Red  
D
E
V
W
Safety Orange  
M
4 TERMINATION / BASE STYLE  
8 term 10 Term  
Termination  
Jumper  
1
2
.250 TAB (QC) no barriers  
.250 TAB (QC) with barriers  
.250 TAB (QC) no barriers  
Solder Lug no barriers  
Solder Lug  
No  
2
A
J
B
K
5
No  
12 ACTUATOR LENS OR BODY LEGEND  
00 - No Legend  
21  
Yes T2 to 5  
3
No  
No  
No  
No  
22  
23  
24  
C
5
D
6
OFF ON  
O
I
Wire Leads no barriers  
Wire Leads  
E
F
25  
O
F
F
26 O  
27 O  
28 I  
Note: Codes J & K for circuits H, G & M.  
N
For additional legend options & codes, visit us at www.carlingtech.com.  
5 ILLUMINATION & SWITCH SEALING  
Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals  
3 & 6 end of switch. Positive (+) and negative (-) symbols apply to LED  
lamps only  
13 LEGEND ORIENTATION  
0
1
2
3
4
No legend (used with codes 21-28 in selection 12)  
Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals  
Orientation 1  
Orientation 2  
Orientation 3  
Orientation 4  
S
C
H
0
3
Z
NONE  
2
2
UP  
3 (+) 7 (–)  
INDEPENDENT 8 (+) 7 (–)  
DOUBLE POLE SWITCHES ONLY  
M
R
1
UP  
3 (+) 6 (–)  
1
2
3
4
6 LOCK  
Lock above terminals 1 & 4 end of switch  
W
lock  
Notes:  
Consult factory to verify horsepower rating for your particular circuit choice.  
1
2
Custom colors are available. Consult factory.  
White imprinting is standard on black actuators; Black imprinting is standard on white,  
red and gray actuators. Custom colors are available, consult factory.  
Only available with 3 position circuits. Center OFF and special circuits only available  
with center position lock function.  
3
4
Additional ratings available. See V-Series Switch Accessories page.  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
V–Series Contura Sealed Rocker Switches - Contura II & III - Dimensional Specifications |  
7
Dimensional Specifications: in. [mm]  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
|
8
V-Series Contura Sealed Rocker Switches - II to XIV - Circuit Diagrams  
Circuit Diagrams:  
CIRCUIT  
CODE  
CIRCUIT  
CODE  
CIRCUIT  
CIRCUIT DIAGRAM  
CODE  
CIRCUIT DIAGRAM  
CIRCUIT DIAGRAM  
3
3
3
3
3
3
3
3
3
6
6
6
6
6
6
6
1
1
1
3
3
3
3
3
3
4
4
4
6
6
6
6
6
6
1
2
3
4
5
6
7
8
A
B
C
D
E
F
J
K
L
2
3
2
2
2
2
2
2
2
2
5
5
5
5
5
5
5
5
2
2
2
2
2
2
5
5
5
5
5
5
2
3
2
1
1
1
1
1
3
3
3
3
3
1
1
1
4
4
4
M
R
S
2
2
2
2
2
1
1
G
H
SYMBOL LEGEND  
SYM.  
DEFINITION  
DESIGNATES TERMINALS AND CONTACTS  
4
DESIGNATES MAINTAINED CIRCUITS  
DESIGNATES OTHER POSITION  
DESIGNATES MOMENTARY CIRCUITS  
DESIGNATES TWO POSITION CONNECTION  
DESIGNATES EXTERNAL JUMPER PROVIDED  
BY CUSTOMER  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
V-Series Contura Sealed Rocker Switches - II to XIV - Lamp Circuit Diagrams, Hazard Warning Circuit Diagrams |  
9
Lamp Circuit Diagrams:  
LAMP CIRCUIT  
CODE  
LAMP CIRCUIT  
CODE  
LAMP CIRCUIT  
CIRCUIT DIAGRAM  
CODE  
LAMP CIRCUIT  
CODE  
CIRCUIT DIAGRAM  
CIRCUIT DIAGRAM  
CIRCUIT DIAGRAM  
+3 +6  
+8  
+8  
+3  
-6  
+3  
-6  
SPECIAL  
#1  
1
1
2
2
2
2
2
1
1
2
A / 1  
B / 2  
C / 3  
D / 4  
E / 5  
F / 6  
G / 7  
H / Z  
J / 8  
L / 9  
M / R  
N / T  
P / V  
U / Y  
-7  
-7  
-7  
+8  
+6  
+3  
+8  
+3  
+3  
-6  
SPECIAL  
#3  
1
2
1
1
2
2
2
-7  
-7  
-7  
+8  
+3  
+3  
+8  
+1 +3 -4 -6  
SPECIAL  
#4  
1
2
2
1
-7  
-7  
-7  
-8  
+1  
+3  
+6  
+6  
+1 +3 -4 -6  
+3  
1
2
1
1
-7  
-7  
+8  
1
+10  
2
+1 +3  
+8  
2
1
K / W  
1
-7  
-9  
-7  
(-)7  
J-Series Hazard Warning Circuit Diagrams:  
CIRCUIT  
CODE  
CIRCUIT  
CODE  
CIRCUIT DIAGRAM  
CIRCUIT DIAGRAM  
1
3
17 18 10(-)  
1
10(-)  
2
1
3
17 18  
J1  
J2  
J3  
J4  
J5  
2
5
8
2
5
8
11 13 3 14  
17 18 10(-)  
1
11 13  
3
14  
6
JA  
5
8
5
1
3
3
17 18 10(-)  
11 13  
3 14  
1
JJ  
NOTE:  
2
2
5
5
8
J circuits are available for all  
non-locking V-Series styles.  
Consult factory for partnumber details.  
1
17 18 10(-)  
11 13  
3 14 15 12  
6
16  
SYMBOL LEGEND  
1
JK  
SYM.  
DEFINITION  
DESIGNATES TERMINALS AND CONTACTS  
DESIGNATES LAMP LOCATION  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
|
10  
V-Series Contura Sealed Rocker Switches - Stand-Alone Components  
Reduce inventory levels and cost by stocking actuators and base switches separately.  
Contura II, III, IV, V, VI, VII, X, XI, XII, XIV Base switches separately: specify V with code selections 2-8 in the ordering schemes.  
Contura II, III, IV, V Actuator only: VV with code A or C for selection 9, & with selections 10-14 in the ordering schemes.  
Contura VI Actuator with lenses and inserts only: VV with code selections 9-16  
Contura II, III, IV, V, VII Actuator only: VV with code A, C, E, G, P or Z for selection 9 & with selections 10-14 in the ordering schemes.  
Contura X, XI, XII, XIV actuators with lenses separately: VV with code selections 9-14 in the ordering schemes.  
Panel Seal: VPS  
Contura X & XI actuators without lenses separately:  
Contura XII actuators without lenses separately:  
VVR 6 1 00 1  
VVP J 1 Z 21 1 00  
1
2
3
Lens  
4
5
1
2
3
Lens  
4
Lens  
5
6
7
Actuator Separately Actuator  
Actuator  
Legend  
Legend  
Orientation  
Actuator  
Style &  
Color  
Legend  
Legend  
Orientation  
Legend  
Style/Color Opening  
Opening Opening  
1 CONTURA X & XI ACTUATOR SEPARATELY  
VVR  
1 CONTURA XII ACTUATOR SEPARATELY  
VVP  
2 ACTUATOR STYLE & COLOR  
2 ACTUATOR STYLE & COLOR  
Black  
Gray  
White  
3
8
Red  
4
J
Black  
K
Gray  
N
White  
M
Red  
Contura X  
Contura XI  
1
6
2
7
9
3,4 LENS OPENING FOR  
No lens Bar lens  
Z
1
2
Square lens  
1
3 LENS OPENING FOR  
1
2
3
4
One bar lens  
5
square lens on top/  
bar lens on bottom  
(Contura X only)  
One bar lenses  
One square lens  
two square lens  
2
5, 7 LENS OR BODY LEGEND  
00 - No Legend  
21  
OFF  
22  
ON  
23  
O
24  
I
25  
O
26 O  
27 O  
28 I  
4 ACTUATOR LENS OR BODY LEGEND  
F
F
N
00 - No Legend this location  
11 ON 12 OFF  
OFF ON  
13  
I
O
14  
O
I
For additional legend options & codes, visit us at www.carlingtech.com.  
15 O O 16 O O 17 O I 18 I O  
F N  
F
N F  
F
3
6 LEGEND ORIENTATION  
0
1
2
No legend  
For additional legend options & codes, visit us at www.carlingtech.com.  
Orientation 1  
Orientation 2  
1
2
1
5 LEGEND ORIENTATION  
0
1
2
3
4
No legend  
Contura X, XI & XII actuator lens assembly separately:  
Orientation 1  
Orientation 2  
Orientation 3  
Orientation 4  
1
2
3
4
VVL 2 1 00 0  
1
2
Lens  
Style  
3
4
5
Lens Separately  
Lens  
Color  
Legend  
Legend  
Orientation  
Contura X, XI & XII top piece of 2-piece lens separately:  
1 CONTURA X, XI & XII LENS SEPARATELY  
VVL  
1 TOP OF LENS SEPARATELY  
VVT  
VVT 1  
3
1
2
2 COLOR  
1 Clear 2 Smoke 3 White  
2 LENS STYLE  
Lens Separately  
Color  
1
2
3
Bar lens  
One Piece Square lens  
Bottom of Two-Piece Square lens  
5
Contura X, XI & XII actuator lens assembly:  
3 TRANSLUCENT LENS COLOR  
4
4
1
Clear  
2
White  
3
Amber  
4
Green  
5
Red  
6 Blue  
top lens  
actuator stem  
2
two piece  
lens assembly  
4 LENS OR BODY LEGEND  
}
00 - No Legend  
21  
22  
ON  
23  
24  
posts mount toward actuator stem  
bottom lens  
OFF  
O
I
1 piece lens/bar lens are positioned the same as bottom lens for assembly,  
minus the top lens. Lenses snap in from bottom.  
25  
O
F
F
26 O  
27 O  
28 I  
N
Notes:  
1
If actuator lens opening for 2 bar or 2 square lenses, legend orientation 0,1, or 2  
must be chosen.  
Center of actuator marking not available for Contura XII.  
Legend is not available for bar style lens.  
For additional legend options & codes, visit us at www.carlingtech.com.  
2
3
4
5
3
5 LEGEND ORIENTATION  
Not recommended with neon lamps.  
0
1
2
3
4
No legend  
Must also order top piece of 2 piece square lens separately.  
Orientation 1  
Orientation 2  
Orientation 3  
Orientation 4  
1
2
3
4
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
V-Series Contura Sealed Rocker Switches - Accessories |  
11  
Easily integrate Contura products into your system, with Contura Accessories  
Contura Connectors  
Q.C. SELECTION GUIDE  
WIRE  
RANGE  
PART NO  
COMPANY  
SERIES  
ORIEN-  
TATION  
TIN  
PLATED  
BRASS  
2
PLAIN  
BRASS  
AWG  
MM  
(REF)  
02965580  
02965471  
02965470  
02965469  
12  
3.0  
12010601  
(2)16-14  
16-14  
20-18  
(2)1.0-2.0  
1.0-2.0  
.5-.8  
TANG  
PACKARD  
58 SERIES  
B
06288318  
12084590  
12052224  
10  
12  
5.0  
3.0  
12015870  
12020035  
12015869  
12052222  
16-14  
(2)22-18  
20-18  
20-22  
16-12  
(2) 16  
18-14  
22-18  
1.0-2.0  
(2).5-.8  
.5-.8  
TANG SYMBOL =  
SHOWS ORIENTATION OF TANG IN SLOT  
PACKARD  
METRI-PACK  
630 SERIES  
A
B
SYMBOL  
12015832  
60253-1  
.35-.5  
1.3-3  
60253-2  
AMP  
(2) 1.3  
.8-2  
250 SERIES  
FASTIN-FASTON  
42100-1  
60295-1  
42100-2  
60295-2  
.3-.9  
NOTE: Consult Delphi Packard and/or Amp on actual part numbers and availability.  
AMP is a registered trademark of AMP Inc. Harrisburg, PA  
Delphi Packard is a registered trademark of Delphi-Packard Electrical Systems Warren, Ohio  
.820[20.83]  
.820[20.83]  
.770[19.56]  
.920[23.37]  
.920[23.37]  
1.170[29.72]  
A
A
B
A
B
A
B
PACKARD 630  
PACKARD 630  
VC2  
PACKARD 630  
PACKARD 630  
VC1  
VC1  
VC2  
.950[24.13]  
B
AMP,  
58  
AMP, PACKARD 58  
AMP  
AMP  
10P3ACKARD  
2
1
8
7 4  
5
69  
10 3  
2
1
8
7
4
5
6 9  
AMP, PACKARD 58  
AMP, PACKARD 58  
3
2
1
8
7
4
5
6
1.266[32.16]  
1.466[37.24]  
1.266[32.16]  
1.466[37.24]  
1.250[31.75]  
MARKING DETAIL  
FRONT VIEW  
MARKING DETAIL  
REAR VIEW  
MARKING DETAIL  
FRONT VIEW  
MARKING DETAIL  
REAR VIEW  
MARKING DETAIL  
FRONT VIEW  
MARKING DETAIL  
REAR VIEW  
VC1  
VC2  
VCH  
CONNECTOR HOUSING  
(For AMP terminals only)  
CONNECTOR HOUSING  
CONNECTOR HOUSING  
Contura X Boot (P/N VB1-01)  
Additional V-Series Ratings  
1
.4VA @ 28VDC Resistive  
4
5
10A 250VAC 1/2 HP, 15A 125 VAC 1/2 HP, No Agency Listings  
10A 250VAC 1/2 HP, 15A 125 VAC 1/2 HP, UL Recognized, CSA Certified  
1
1.050[26.67]  
B
C
D
E
F
G
H
L
15A 24V  
20A 18V  
20A 12V  
2.000[50.80]  
20A 14V, 10A 14VT (circuits 1, 4, A, & D only)  
10A 14V, 6A, 14VT (circuit G only)  
20A 6V  
.757[19.23]  
20A 3V  
2
15A 125 VAC, 10A 250VAC, 1/2 HP 125-250 VAC; 6A 125 VAC L  
.4VA/20A 12V (combi-contact)  
M
(combination gold/silver contacts for borderline dry circuit applications)  
.4VA/15A 24V (combi-contact)  
(combination gold/silver contacts for borderline dry circuit applications)  
N
Contura II, III, IV, V, VI & VII Actuator  
Removal Tool (P/N VRT)  
3.99 [101.35]  
NOTES  
Consult factory to determine availability for individual circuits and their HP rating.  
O T P  
1.  
2.  
Not available with Contura 7 or 14 rocker styles.  
Rating L available with circuits 1, 4, A & D only.  
INSERT POINTS UNDER  
ACTUATOR  
HOLD FLUSH ON BRACKET AND PUSH  
IN  
.900 [22.86]  
TOP  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
|
12  
V-Series Contura Sealed Rocker Switches - Accessories  
Contura Mounting Panels  
Dimensional Specifications: in. [mm]  
Contura Hole Plug  
Dimensional Specifications: in. [mm]  
1.450 [36.83]  
TEST CUT  
HOLE IN  
VHP  
.830 [21.08]  
ACTUAL  
CONTURA II,III HOLE PLUG  
MATERIAL  
1.240 [31.50]  
1.820 [46.23]  
VHP  
CONTURA II,III HOLE PLUG  
.430 [10.92]  
VH2  
STANDARD HOLE PLUG  
(With wing serrations)  
VH1  
STANDARD HOLE PLUG  
(No wing serrations)  
2.000 [50.80]  
(With VC1 connector attached)  
1.067 [27.10]  
DETAIL VIEW  
VH1,VH3 & VH5  
HOLE PLUGS  
(No wing serrations  
for ease of removal)  
VH3  
VH4  
CONTURA IV HOLE PLUG  
(No wing serrations)  
CONTURA IV HOLE PLUG  
(With wing serrations)  
1.928 [48.97]  
1.020 [25.91]  
DETAIL VIEW  
VH2,VH4 & VH6  
HOLE PLUGS  
VH5  
VH6  
CONTURA V HOLE PLUG  
(No wing serrations)  
CONTURA V HOLE PLUG  
(With wing serrations)  
(With wing serrations)  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
|
Reps & Contact  
13  
Authorized Sales Representatives and Distributors  
Click on a region of the map below to find your local representatives and distributors or visit  
www.carlingtech.com/findarep.  
CANADA  
EUROPE  
USA  
MIDDLE  
EAST  
MEXICO  
AFRICA  
ASIA-PACIFIC  
OCEANIA  
SOUTH  
AMERICA  
About Carling  
Founded in 1920, Carling Technologies is a leading manufacturer of electrical and electronic switches  
and assemblies, circuit breakers, electronic controls, power distribution units, and multiplexed power  
distribution systems. With four ISO registered manufacturing facilities and technical sales offices worldwide,  
Carling Technologies Sales, Service and Engineering teams do much more than manufacture electrical  
components, they engineer powerful solutions! To learn more about Carling please visit  
www.carlingtech.com/company-profile.  
To view all of Carling’s environmental, quality, health & safety certifications please visit  
www.carlingtech.com/environmental-certifications  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
Worldwide Headquarters  
Carling Technologies, Inc.  
60 Johnson Avenue, Plainville, CT 06062  
Phone: 860.793.9281 Fax: 860.793.9231  
@
Email: sales carlingtech.com  
@
Northern Region Sales Office: nrsm carlingtech.com  
@
Southeast Region Sales Office: sersm carlingtech.com  
@
Midwest Region Sales Office: mrsm carlingtech.com  
@
West Region Sales Office: wrsm carlingtech.com  
@
Latin America Sales Office: larsm carlingtech.com  
Asia-Pacific Headquarters  
Carling Technologies, Asia-Pacific Ltd.,  
Suite 1607, 16/F Tower 2, The Gateway,  
Harbour City, 25 Canton Road,  
Tsimshatsui, Kowloon, Hong Kong  
Phone: Int + 852-2737-2277 Fax: Int + 852-2736-9332  
@
Email: sales carlingtech.com.hk  
@
Shenzhen, China: shenzhen carlingtech.com  
@
Shanghai, China: shanghai carlingtech.com  
@
Pune, India: india carlingtech.com  
@
Kaohsiung, Taiwan: taiwan carlingtech.com  
@
Yokohama, Japan: japan carlingtech.com  
|
|
Europe Middle East Africa Headquarters  
Carling Technologies LTD  
4 Airport Business Park, Exeter Airport,  
Clyst Honiton, Exeter, Devon, EX5 2UL, UK  
Phone: Int + 44 1392.364422 Fax: Int + 44 1392.364477  
@
Email: ltd.sales carlingtech.com  
@
Germany: gmbh carlingtech.com  
@
France: sas carlingtech.com  
www.carlingtech.com  
REV_05_2017  

相关型号:

VDB2HWP1-1AAB1-3-XRG1

Rocker Switch, DPDT, On-on, Maintained, 15A, 24VDC, Quick Connect Terminal, Rocker Actuator, Panel Mount,

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
Carling Techn

VDB2HWP1-1FMB1-3

Rocker Switch, DPDT, On-on, Maintained, 15A, 24VDC, Quick Connect Terminal, Rocker Actuator, Panel Mount,

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
Carling Techn

VDB2HWVC-A8DXX-1-XTC1

Rocker Switch, DPDT, On-on, Maintained, 15A, 24VDC, Quick Connect Terminal, Rocker Actuator, Panel Mount,

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
Carling Techn

VDB2HYVB-UHLY3-1

Rocker Switch, DPDT, On-on, Maintained, 15A, 24VDC, Quick Connect Terminal, Rocker Actuator, Panel Mount,

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
Carling Techn

VDB2MWJB-A8DA5-1

Rocker Switch, DPDT, On-on, Maintained, 15A, 24VDC, Quick Connect Terminal, Rocker Actuator, Panel Mount,

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
Carling Techn

VDB2SY0C-UZM6D-3-XSV2

Rocker Switch, DPDT, On-on, Maintained, 15A, 24VDC, Quick Connect Terminal, Rocker Actuator, Panel Mount,

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
Carling Techn

VDB2UCCC-ANC00-000

Rocker Switch, DPDT, On-on, Maintained, 15A, 24VDC, Quick Connect Terminal, Rocker Actuator, Panel Mount,

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
Carling Techn

VDB2UJJB-AXC00-000-XLT1

Rocker Switch, DPDT, On-on, Maintained, 15A, 24VDC, Quick Connect Terminal, Rocker Actuator, Panel Mount,

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
Carling Techn

VDB2UJJB-EAC31-2AW

Rocker Switch, DPDT, On-on, Maintained, 15A, 24VDC, Quick Connect Terminal, Rocker Actuator, Panel Mount,

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
Carling Techn

VDB2UJXB-EACM4-100-XPP1

Rocker Switch, DPDT, On-on, Maintained, 15A, 24VDC, Quick Connect Terminal, Rocker Actuator, Panel Mount,

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
Carling Techn

VDB2UJXB-EACM8-100-XPM1

Rocker Switch, DPDT, On-on, Maintained, 15A, 24VDC, Quick Connect Terminal, Rocker Actuator, Panel Mount,

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
Carling Techn

VDB2UXXB-ASC70-100-XBV1

Rocker Switch, DPDT, On-on, Maintained, 15A, 24VDC, Quick Connect Terminal, Rocker Actuator, Panel Mount,

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
Carling Techn